Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.817
Filtrar
1.
Nat Commun ; 15(1): 2828, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565532

RESUMO

Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called 'personalized lag time'. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.


Assuntos
Lentes de Contato Hidrofílicas , Diabetes Mellitus , Animais , Humanos , Glucose/análise , Glicemia , Lágrimas/química , Diabetes Mellitus/diagnóstico
2.
Lab Chip ; 24(8): 2327-2334, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38563256

RESUMO

The eyes provide rich physiological information and offer diagnostic potential as a sensing site, and probing tear constituents via the wearable contact lens could be explored for healthcare monitoring. Herein, we propose a novel adhesive contrast contact lens platform that can split tear film by natural means of tear secretion and blinking. The adhesive contrast is realized by selective grafting of a lubricant onto a polydimethylsiloxane (PDMS)-based contact lens, leading to high pinning zones on a non-adhesive background. The difference in contact angle hysteresis facilitates the liquid splitting. Further, the method offers control over the droplet volume by controlling the zone dimension. The adhesive contrast contact lens is coupled with fluorescent spectroscopic as well as colorimetric techniques to realize its potential as a diagnostic platform. The adhesive contrast contact lens is exploited to detect the level of lactoferrin in tear by sensitizing split droplets with Tb3+ ions. The adhesive contrast contact lens integrated with a fluorescence spectrometer was able to detect the lactoferrin level up to a concentration of 0.25 mg mL-1. Additionally, a colorimetric detection based on the fluorescence of the lactoferrin-terbium complex is demonstrated for the measurement of lactoferrin, with a limit of detection in the physiological range up to 0.5 mg mL-1.


Assuntos
Lentes de Contato Hidrofílicas , Lactoferrina/análise , Olho , Lágrimas/química , Piscadela
3.
Sci Rep ; 14(1): 8592, 2024 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615153

RESUMO

Multifocal contact lenses (MCLs) are one of the solutions to correct presbyopia, but their adoption is not widespread. To address this situation, visual simulators can be used to refine the adaptation process. This study aims to obtain accurate simulations for a visual simulator (SimVis Gekko; 2EyesVision) of daily soft MCL designs from four manufacturers. In-vitro characterization of these MCLs-several powers and additions- was obtained using NIMO TR-1504. From the averaged relative power profiles across powers, phase maps were reconstructed and the Through-Focus Visual Strehl metric was calculated for each MCL design. The SimVis Gekko simulation corresponding to each MCL design was obtained computationally and bench-validated. Finally, the MCL simulations were clinically validated involving presbyopic patients. The clinical validation results show a good agreement between the SimVis Gekko simulations and the real MCLs for through-focus visual acuity (TF-VA) curves and VA at three real distances. All MCL designs showed a partial correlation higher than 0.90 and a Root Mean Square Error below 0.07 logMAR between the TF-VA of simulations and Real MCLs across subjects. The validity of the simulation approach using SimVis Gekko and in-vitro measurements was confirmed in this study, opening the possibility to accelerate the adaptation of MCLs.


Assuntos
Lentes de Contato Hidrofílicas , Lagartos , Presbiopia , Humanos , Animais , Simulação por Computador , Presbiopia/terapia , Acuidade Visual
4.
BMC Ophthalmol ; 24(1): 173, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627653

RESUMO

OBJECTIVES: This study aims to compare the efficacy of peripheral add multifocal soft contact lenses (SCLs) (excluding bifocal SCLs) with single vision contact lenses or spectacles in controlling myopia progression. METHOD: A comprehensive literature search was conducted in the Pubmed, EMBASE, Web of Science, and Cochrane Library databases until October 2023. The literature was thoroughly screened based on predetermined eligibility criteria. Pooled odds ratios (ORs) were calculated for dichotomous data and weighted mean differences (WMD) for continuous data. RESULTS: A total of 11 articles comprising 787 participants were included in this meta-analysis. Our pooled results demonstrated that the peripheral add multifocal SCLs groups exhibited significantly reduced refraction progression (MD = 0.20; 95%CI, 0.14 ∼ 0.27; P<0.001) and less axial length elongation (MD=-0.08; 95%CI, -0.09∼-0.08; P<0.001) compared to the control group. There was no significant difference in high-contrast logMAR distance visual acuity between the two groups (MD = 0.01; 95%CI, -0.00 ∼ 0.02; P = 0.19). However, the group using single-vision lenses had better low-contrast logMAR distance visual acuity compared to those using peripheral add multifocal SCLs (MD = 0.06; 95%CI, 0.02 ∼ 0.10; P = 0.004). Data synthesis using a random-effects model indicated an incidence of contact lens-related adverse events of 0.065 (95%CI, 0.048 ∼ 0.083). CONCLUSIONS: The present meta-analysis signifies that peripheral defocus modifying contact lenses are effective in slowing down the progression of myopia and reducing axial elongation.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Humanos , Miopia/terapia , Acuidade Visual , Lentes de Contato Hidrofílicas/efeitos adversos , Refração Ocular , Testes Visuais , Transtornos da Visão
5.
PLoS One ; 19(3): e0296279, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38507419

RESUMO

PURPOSE: To investigate trends in contact lens usage in a nationally representative sample of the Korean population in 2021. METHODS: For this retrospective study, we analyzed data of 3,601 Korean participants aged 10-59 years, from the Korea National Health and Nutrition Examination Survey (KNHANES 2021 version), who underwent eye examination, of whom 1,136 individuals (274 men and 862 women) were contact lens users. The demographic trend among Korean contact lens wearers was examined using statistical analyses to investigate the changes in their contact lens-wearing experience, duration of lens use, type of lens used, location of purchase, presence of an Eye Care Practitioner(ECP)'s prescription, lens-related ophthalmic complications, and type of lenses worn at the time of complications, according to sex. Multivariable logistic regression analysis was conducted to examine the association of each variable with the rate of complications and use of soft lenses. RESULTS: The average age of the contact lens users was 33.42±0.33 years, with 70.36% (weighted percentage) of users being women who used contact lenses for significantly longer periods than men (p<0.001). Additionally, only wearing of cosmetic lenses was significantly correlated with the occurrence of complications (p = 0.006), and 6.76% of users purchased lenses without a prescription. Multivariate analysis among the contact lens users revealed a significant relationship between the complication rate and female sex (p = 0.002), pre-existing eye disease diagnosed by ECPs (p = 0.0288), and duration of contact lens use (p<0.0001). CONCLUSION: We identified sex differences in contact lens usage trends in Korea. The main changes observed were an increase in middle-aged lens users and a decrease in female users compared to that in the early 2000s. In addition, contact lens complications were significantly associated with sex and pre-existing eye disease. Therefore, those wearing contact lenses for extended periods should exercise caution and consult eye care specialists in the presence of any symptoms.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Oftalmopatias , Pessoa de Meia-Idade , Humanos , Feminino , Masculino , Adulto , Estudos de Coortes , Estudos Retrospectivos , Inquéritos Nutricionais , Lentes de Contato/efeitos adversos , Projetos de Pesquisa , Oftalmopatias/diagnóstico , República da Coreia/epidemiologia , Lentes de Contato Hidrofílicas/efeitos adversos
6.
BMC Ophthalmol ; 24(1): 141, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549070

RESUMO

PURPOSE: In the present study, we aimed to evaluate the efficacy of the bandage contact lens (BCLs) in the treatment of dry eye disease (DED) after complicated cataract or/and intraocular lens (IOL) surgery. METHODS: In this retrospective, single-centered, observational study, we collected data from 69 patients who underwent complicated cataract or/and IOL surgery. Of these, 35 cases wore their own BCLs immediately after the operation, while the other 34 cases did not have their own BCLs and were instead covered with gauze. The Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp microscope examination, keratograph analysis, and Schirmer I test were measured at baseline, 1 week and 1 month postoperatively. RESULTS: In the BCL group, the score of the OSDI questionnaire was significantly decreased at 1 week and 1 month postoperatively compared with baseline levels (P = 0.000, collectively). Moreover, the fluorescein staining score of the BCL group was remarkably decreased 1-week and 1-month postoperatively compared with the non-BCL group (P = 0.000 and P = 0.000, respectively). Furthermore, the redness score of the BCL group was also better compared with the non-BCL group at 1 week and 1 month postoperatively (P = 0.014 and P = 0.004, respectively). CONCLUSIONS: Complicated cataract or/and IOL surgery would intensify the DED. Early application of BCLs postoperatively improved patients' comfort and alleviated dry eye-related symptoms and signs. Furthermore, this mechanism might involve the acceleration of corneal epithelial healing, the alleviation of ocular stress response and the stabilization of the tear film. TRIAL REGISTRATION: Trial registration ClinicalTrials, NCT04120389. Registered 10 October 2019-retrospectively registered.


Assuntos
Catarata , Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Lentes Intraoculares , Humanos , Estudos Retrospectivos , Lentes Intraoculares/efeitos adversos , Catarata/complicações , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/diagnóstico , Lentes de Contato Hidrofílicas/efeitos adversos , Bandagens/efeitos adversos
7.
Optom Vis Sci ; 101(3): 134-142, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546754

RESUMO

SIGNIFICANCE: The availability of a range of effective myopia control modalities enables the clinician to exercise judgment when discussing the treatment plan with the patient and their parents. This article outlines important considerations beyond efficacy.Clinically meaningful myopia control may be attained with some spectacle lenses, select soft contact lenses, some concentrations of atropine, and overnight orthokeratology. Given that satisfactory efficacy can be achieved with a range of modalities, other factors should be considered when deciding upon the best intervention for a given child. Four key factors-compliance, quality of vision, quality of life, and safety-are discussed in this review. Compliance directly impacts efficacy regardless of the modality and is the most important consideration, as it is influenced by quality of vision and comfort. Daily disposal myopia control contact lenses and overnight orthokeratology are generally associated with high compliance, provide better vision-related quality of life than spectacles, and carry a very low risk when used appropriately. A further benefit of overnight orthokeratology is the elimination of a need for optical correction during the day.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Criança , Humanos , Qualidade de Vida , Miopia/terapia , Atropina , Exercício Físico
8.
Int Ophthalmol ; 44(1): 136, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485796

RESUMO

BACKGROUND: The surface wettability of soft contact lenses (SCLs) affects the wearing comfort. Verofilcon A is a daily disposable silicone hydrogel contact lens with SMARTSURFACE® technology, ensuring high surface wettability. PURPOSE: To evaluate tear stability on the surface of verofilcon A and narafilcon A SCLs and correlate these findings with clinical parameters and patients' discomfort. METHODS: Sixty-two SCL wearers (124 eyes) with SCL discomfort were randomly assigned to use narafilcon A (control SCL) and verofilcon A for 2 weeks each by crossover. The noninvasive tear break-up time (NIBUT) of the naked eye at baseline and pre-lens NIBUT (PL-NIBUT) of the SCL surface after 2 weeks of using each SCL were measured using the DR-1α® dry eye observation device. Corneal superficial punctate keratopathy (SPK) (0-3) and conjunctival hyperemia (0-3), and comfort level of SCL wear (1-10) were also evaluated. RESULTS: NIBUT and PL-NIBUT values were 4.6 ± 2.3 s for the naked eye, 6.6 ± 6.6 s for narafilcon A, and 11.3 ± 3.5 s for verofilcon A. verofilcon A had significantly higher PL-NIBUT than the naked eye and narafilcon A (p < 0.05). SPK (0.16 ± 0.48 vs. 0.00 ± 0.00, p < 0.01) and conjunctival hyperemia (1.15 ± 0.82 vs. 0.49 ± 0.50, p < 0.01) scores were lower when wearing verofilcon A than narafilcon A. The ocular comfort score of wearing SCLs was higher with verofilcon A than with narafilcon A (8.7 ± 1.8 vs. 9.8 ± 0.5, p < 0.01). The ocular comfort score for wearing verofilcon A was higher, regardless of the baseline NIBUT. CONCLUSION: The results of this study showed a consistent surface-wetting advantage of verofilcon A in patients with ocular discomfort. verofilcon A was used comfortably in patients with low NIBUT scores at baseline. The findings suggest that verofilcon A is recommended for SCL wearers experiencing SCL-related dry eye symptoms and discomfort.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Hiperemia , Humanos , Hidrogéis , Silicones , Síndromes do Olho Seco/etiologia , Lágrimas
9.
Int J Mol Sci ; 25(5)2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38473902

RESUMO

The increase in bacterial resistance to antibiotics in recent years demands innovative strategies for the detection and combating of biofilms, which are notoriously resilient. Biofilms, particularly those on contact lenses, can lead to biofilm-related infections (e.g., conjunctivitis and keratitis), posing a significant risk to patients. Non-destructive and non-contact sensing techniques are essential in addressing this threat. Digital holographic tomography emerges as a promising solution. This allows for the 3D reconstruction of the refractive index distribution in biological samples, enabling label-free visualization and the quantitative analysis of biofilms. This tool provides insight into the dynamics of biofilm formation and maturation on the surface of transparent materials. Applying digital holographic tomography for biofilm examination has the potential to advance our ability to combat the antibiotic bacterial resistance crisis. A recent study focused on characterizing biofilm formation and maturation on six soft contact lens materials (three silicone hydrogels, three hydrogels), with a particular emphasis on Staphylococcus epidermis and Pseudomonas aeruginosa, both common culprits in ocular infections. The results revealed species- and time-dependent variations in the refractive indexes and volumes of biofilms, shedding light on cell dynamics, cell death, and contact lens material-related factors. The use of digital holographic tomography enables the quantitative analysis of biofilm dynamics, providing us with a better understanding and characterization of bacterial biofilms.


Assuntos
Biofilmes , Lentes de Contato Hidrofílicas , Humanos , Bactérias , Antibacterianos , Hidrogéis , Lentes de Contato Hidrofílicas/microbiologia , Pseudomonas aeruginosa/fisiologia
10.
Eye Contact Lens ; 50(4): 171-176, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38345090

RESUMO

OBJECTIVES: Center-distance multifocal contact lenses (MFCLs) are used to slow myopia progression. We examined the effect of two MFCLs on intraocular straylight values in myopic individuals. METHODS: Twenty-five young myopic adults were enrolled and were fit with three contact lenses (Biofinity sphere, Biofinity Multifocal, and NaturalVue Multifocal) in a random order over two study visits. Pupil size (NeurOptics VIP-300, Laguna Hills, CA) and contact lens centration were measured. Right eye intraocular straylight measurements were collected (OCULUS C-Quant; Wetzlar, Germany) and compared with a spectacle trial lens. Log straylight (LogSL) values and straylight residuals were analyzed using repeated-measures analyses of variance with Tukey-corrected post hoc t -tests. RESULTS: The mean participant age (±SD) was 24.1±1.5 years, and right eye spherical equivalent refractive error was -3.38±1.53 DS. There was no difference in mesopic pupil size between visits ( P =0.68) and no difference in contact lens centration between lenses ( P =0.99). LogSL values differed by lens type ( P =0.004). LogSL with the spectacle trial lens was significantly greater than with each contact lens type (all P <0.05), but there were no significant differences in LogSL between the three contact lenses (all P >0.05). There was no difference between the three contact lens designs for straylight residuals ( P =0.33). CONCLUSIONS: Measured intraocular straylight for both MFCLs was not different than with a spherical soft contact lens. A significant increase in intraocular straylight with spectacle trial lens correction was observed compared with all contact lenses.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Adulto , Humanos , Adulto Jovem , Acuidade Visual , Refração Ocular , Miopia/terapia , Olho
11.
Cont Lens Anterior Eye ; 47(2): 102128, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38342732

RESUMO

PURPOSE: This study aimed to report the pattern of contact lens prescribing from the Gulf Cooperation Council (GCC) countries. METHODS: Optometrists in the GCC region were contacted to participate in a web-based survey hosted on Qualtrics XM (Provo, Utah, USA). The survey methodology was adapted from the International Contact Lens Prescribing Consortium, and participants were asked to report their last five lens fits. It collected information on practitioner demographics (age, gender, nationality, qualification, country of practice, and number of years of experience), CL user demographics (age and gender) and on lens specific details such as lens type, lens design, lens material, replacement plan, and modality of lens wear. Descriptive statistics were used to analyse and report the data. RESULTS: This study reports 739 contact lens fits by 174 practitioners from six GCC countries. The average age of the patients was 29.72 ± 9.07 (Mean ± SD) years and 64 % of them were females. The majority (80.2 %) were fitted with soft contact lenses, with 59 % preferring silicone hydrogels, 20 % wearing them for cosmetic purposes and nearly half of them disposed of their lenses daily (55 %). Among the RGP lenses, 41 % were scleral lenses. This survey demonstrated a greater proportion of new lens fits (55 % vs. 37 %), disposable hydrogel lens use (21 % vs. 13 %), and a preference for cosmetic contact lenses (20 % vs. 4 %) compared to the international data. CONCLUSION: The pattern of CL prescriptions in the GCC region closely resembled the global trend. The survey observed a higher preference towards frequent replacement soft lenses, a greater proportion of silicone hydrogel lenses, a higher percentage of rigid lens fits, a greater affinity for cosmetic contact lenses, and a higher percentage of new fits. These trends suggest that contact lens prescription habits in the region are likely to continue evolving in the future.


Assuntos
Lentes de Contato Hidrofílicas , Optometria , Feminino , Humanos , Adulto Jovem , Adulto , Masculino , Inquéritos e Questionários , Prescrições , Hidrogéis , Silicones
12.
Cont Lens Anterior Eye ; 47(2): 102126, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38342733

RESUMO

OBJECTIVE: Despite the increasing prevalence of contact lens (CL) wear, knowledge and compliance with proper care remain suboptimal. This study aims to assess the level of knowledge and compliance with lens care practices in patients attending a third-level institution in Northeast Mexico. METHODS: A cross-sectional study using a self-administered online survey was conducted. Patients at the Instituto Tecnolgico de Monterrey were invited to participate. The questionnaire consisted of three sections: demographic data and CL information, CL practices, and CL care knowledge. Participants responding correctly to 6/7 questions from the second and third sections were classified as having good compliance and good knowledge, respectively. Predictive factors for good compliance and knowledge were calculated using a logistic regression model. RESULTS: A total of 287 users participated in the study. The median age was 25 (14-78) years with a female (n = 221, 77 %) predominance. Good knowledge was observed in 215 (74.9 %), whereas only 42 (14.6 %) presented good compliance. Failing to replace CL as prescribed (n = 199, 69.3 %) and sleeping with the devices (n = 198, 69 %) were the most frequent practices causing non-compliance. Whereas prohibition of swimming with CL was the least known practice (n = 74, 25 %). Users with recent (≤5 years) wearing experience were more likely to present good knowledge (OR 2.19, p = 0.014) and compliance (OR 3.15, p < 00.01). No statistical correlation was established between knowledge and compliance. CONCLUSION: Non-compliance and lack of knowledge of proper CL care were prevalent among in this population. Long-term CL users were at higher risk of non-compliance and lack of knowledge. Moreover, knowledge was not related to compliance; therefore, different strategies must be implemented to reduce CL misconduct.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Humanos , Feminino , Adulto , Estudos Transversais , México/epidemiologia , Soluções para Lentes de Contato , Cooperação do Paciente
13.
Eye Contact Lens ; 50(4): 177-182, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305377

RESUMO

PURPOSE: To evaluate a new in vitro technique for measuring soft contact lens wettability using a nonmodified commercial videokeratoscope, the Medmont E300. To this end, the capability of different artificial tears containing hyaluronic acid (HA) to improve soft contact lens wettability in vitro was investigated. METHODS: An experimental in vitro study was conducted to assess the wetting properties of three artificial tears containing different concentrations of HA (0.1%, 0.2%, and 0.3%) on soft contact lenses. A saline solution was used as the control. For each solution, 15 hydrogel (Ocufilcon D) contact lenses and 15 silicone-hydrogel (Somofilcon A) contact lenses were evaluated. The in vitro wettability of the lenses was measured using the Medmont E300 with a self-developed technique, which involved measuring the tear film surface quality (TFSQ) mean, TFSQ area, TFSQ central, and TFSQ inferior. RESULTS: Compared with the saline solution, all the concentration of HA (0.1%, 0.2%, and 0.3%) improved the in vitro wettability of both soft contact lenses by decreasing their TFSQ mean and TFSQ area ( P <0.05). Regression models revealed an exponential relationship between contact lens wettability and the concentration of HA for both soft contact lenses ( R >0.5, P <0.05). Furthermore, the hydrogel contact lens presented a wetter surface than the silicone-hydrogel contact lens ( P <0.05). CONCLUSIONS: The measurement of in vitro wettability of soft contact lenses with a nonmodified Medmont E300 seems to be a useful technique to evaluate the wetting properties of contact lens products.


Assuntos
Lentes de Contato Hidrofílicas , Lubrificantes Oftálmicos , Humanos , Molhabilidade , Solução Salina , Hidrogéis , Silicones
14.
Cont Lens Anterior Eye ; 47(2): 102129, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38423868

RESUMO

PURPOSE: To evaluate the in vitro wettability and coefficient of friction of a novel amphiphilic polymeric surfactant (APS), poly(oxyethylene)-co-poly(oxybutylene) (PEO-PBO) releasing silicone hydrogel (SiHy) contact lens material (serafilcon A), compared to other reusable SiHy lens materials. METHODS: The release of fluorescently-labelled nitrobenzoxadiazole (NBD)-PEO-PBO was evaluated from serafilcon A over 7 days in a vial. The wettability and coefficient of friction of serafilcon A and three contemporary SiHy contact lens materials (senofilcon A; samfilcon A; comfilcon A) were evaluated using an in vitro blink model over their recommended wearing period; t = 0, 1, 7, 14 days for all lens types and t = 30 days for samfilcon A and comfilcon A (n = 4). Sessile drop contact angles were determined and in vitro non-invasive keratographic break-up time (NIKBUT) measurements were assessed on a blink model via the OCULUS Keratograph 5 M. The coefficient of friction was measured using a nano tribometer. RESULTS: The relative fluorescence of NBD-PEO-PBO decreased in serafilcon A by approximately 18 % after 7 days. The amount of NBD-PEO-PBO released on day 7 was 50 % less than the amount released on day 1 (6.5±1.0 vs 3.4±0.5 µg/lens). The reduction in PEO-PBO in the lens also coincided with an increase in contact angles for serafilcon A after 7 days (p < 0.05), although there were no changes in NIKBUT or coefficient of friction (p > 0.05). The other contact lens materials had stable contact angles and NIKBUT over their recommended wearing period (p > 0.05), with the exception of samfilcon A, which had an increase in contact angle after 14 days as compared to t = 0 (p < 0.05). Senofilcon A and samfilcon A also showed an increase in coefficient of friction at 14 and 30 days, respectively, compared to their blister pack values (p < 0.05). CONCLUSION: The results indicate that serafilcon A gradually depletes its reserve of PEO-PBO over 1 week, but this decrease did not significantly change the lens performance in vitro during this time frame.


Assuntos
Lentes de Contato Hidrofílicas , Silicones , Humanos , Molhabilidade , Hidrogéis , Fricção
15.
Int Ophthalmol ; 44(1): 39, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334808

RESUMO

PURPOSE: To evaluate the correlation between clinical tests, patient symptoms, and conjunctivochalasis in contact lens wearers and non-wearers. METHODS: This study comprised 40 eyes of 40 current soft contact lens users and 40 eyes of 40 control subjects. Cross-sectional areas of conjunctivochalasis at three locations (nasal, central, temporal) during straight and downward gazes were determined using anterior segment optical coherence tomography in all participants. Tear film break up time test and Schirmer test with anesthesia were performed and for evaluation of symptoms, the participants completed ocular surface disease index questionnaire. RESULTS: During straight gaze, the mean cross-sectional areas of conjunctivochalasis were 0.0112 ± 0.009 and 0.006 ± 0.005 mm2 at nasal, 0.0096 ± 0.007 and 0.002 ± 0.004 mm2 at central, 0.0176 ± 0.014 and 0.008 ± 0.009 mm2 at temporal in contact lens and control groups, respectively. Regardless of location and gaze direction, the mean cross-sectional conjunctivachalasis areas of the contact lens group were significantly higher than those of the controls (all, p < 0.05). Significant positive correlations between ocular surface disease index score and measured conjunctivachalasis areas (in all sites) during straight gaze and downward gaze were observed in the contact lens group (all, p < 0.05 and r > 0.450). CONCLUSION: Wearing soft contact lenses is associated with increased conjunctivochalasis areas. Anterior segment optical coherence tomography determined conjunctivochalasis area is an objective clinical measurement value that is positively correlated with patients' symptoms in soft contact lens wearers.


Assuntos
Doenças da Túnica Conjuntiva , Lentes de Contato Hidrofílicas , Humanos , Doenças da Túnica Conjuntiva/diagnóstico , Doenças da Túnica Conjuntiva/epidemiologia , Doenças da Túnica Conjuntiva/etiologia , Lentes de Contato Hidrofílicas/efeitos adversos , Olho , Tomografia de Coerência Óptica , Lágrimas
16.
Ophthalmic Physiol Opt ; 44(2): 321-333, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38303152

RESUMO

PURPOSE: To measure the dynamic accommodation response (AR) to step stimuli with and without multifocal contact lenses (MFCLs), in emmetropes and myopes. METHODS: Twenty-two adult subjects viewed alternating distance (0.25D) and near (3D) Maltese crosses placed in free space, through two contact lens types: single vision (SVCL) or centre-distance multifocal (MFCL; +2.50D add). The AR level was measured along with near to far (N-F) and far to near (F-N) step response characteristics: percentage of correct responses, magnitude, latency, peak velocity and duration of step response. RESULTS: There was no difference between N-F and F-N responses, or between refractive groups in any aspect of the accommodation step response dynamics. The percentage of correct responses was unaffected by contact lens type. Through MFCLs, subjects demonstrated smaller magnitude, longer latency, shorter duration and slower peak velocity steps than through SVCLs. When viewing the near target, the AR through MFCLs was significantly lower than through SVCLs. When viewing the distance target with the MFCL, the focal points from rays travelling through the distance and near zones were approximately 0.004D behind and 2.50D in front of the retina, respectively. When viewing the near target, the respective values were approximately 1.89D behind and 0.61D in front of the retina. CONCLUSION: The defocus error required for accommodation control appears not to be solely derived from the distance zone of the MFCL. This results in reduced performance in response to abruptly changing vergence stimuli; however, these errors were small and unlikely to impact everyday visual tasks. There was a decrease in ocular accommodation during near tasks, which has previously been correlated with a reduced myopic treatment response through these lenses. With MFCLs, the estimated dioptric myopic defocus was the largest when viewing a distant stimulus, supporting the hypothesis that the outdoors provides a beneficial visual environment to reduce myopia progression.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Miopia , Adulto , Humanos , Refração Ocular , Testes Visuais , Emetropia , Acomodação Ocular , Miopia/terapia
17.
Carbohydr Polym ; 331: 121880, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38388063

RESUMO

Contact lenses (CLs) constitute an advantageous platform for the topical release of corticosteroids due to their prolonged contact with the eye. However, the lipophilic nature of corticosteroids hampers CLs' ability to release therapeutic amounts. Two approaches to improve loading and release of triamcinolone acetonide (TA) from poly(2-hydroxyethyl methacrylate)-based hydrogels were investigated: adding 2-hydroxypropyl-ß-cyclodextrin (HP-ß-CD) to the monomers solution before polymerization (HEMA/i-CD) and an hydrogels' post-treatment with HP-ß-CD (HEMA/p-CD). The effect of HP-ß-CD and sterilization by high hydrostatic pressure (HHP) on the hydrogel properties (water content, oxygen and ion permeability, roughness, transmittance, and stiffness) was evaluated. The HEMA/i-CD hydrogels had stronger affinity for TA, sustaining its release for one day. HHP sterilization promoted the formation of cyclodextrin-TA complexes within the hydrogels, improving their drug-loading capacity ¼60 %. Cytotoxicity and irritability tests confirmed the safety of the therapeutic CLs. TA released from the hydrogels permeated through ocular tissues ex vivo and showed anti-inflammatory activity. Finally, a previously validated mathematical model was used to estimate the ability of the TA-loaded CLs to deliver therapeutic drug concentrations to the posterior part of the eye. Overall, HP-ß-CD-containing CLs are promising candidates for the topical ocular application of TA as an alternative delivery system to intraocular injections.


Assuntos
Lentes de Contato Hidrofílicas , Ciclodextrinas , Metacrilatos , Triancinolona Acetonida/farmacologia , 2-Hidroxipropil-beta-Ciclodextrina , Pressão Hidrostática , Corticosteroides , Hidrogéis
18.
Cont Lens Anterior Eye ; 47(2): 102105, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38216392

RESUMO

PURPOSE: The current multi-study analysis combined data from three studies to quantify the relationship between the initial reaction to soft multifocal contact lens (MFCL) design types at dispensing and evaluate the predictability of overall vision satisfaction (OVS) and intention to purchase (ITP) after 1 week of wear. METHOD: Three prospective studies tested MFCLs over 1-week of wear following the same protocol, using a range of potentially predictive ratings at dispensing, and both OVS and ITP at 1-week as an indicator acceptance level. In each study, two of MyDay® multifocal, clariti® 1 day multifocal, Biofinity® multifocal (worn as a daily disposable lens) or 1 DAY ACUVUE® MOIST MULTIFOCAL were dispensed for 1-week of daily wear. OVS was recorded on a 100-point VAS and ITP on a 5-point LIKERT scale. Fourteen possible predictors were entered in the statistical model, and predictability was assessed using Chi-square Automatic Interaction Detector (CHAID) statistical test. RESULTS: A total of 210 participants (152 female & 58 male; 53.9 ± 6.5 years, range 41-71 years), representing 420 MFCL fits, equally distributed between emergent n = 65, established n = 70 and advanced n = 75 presbyopes, completed the studies. OVS on dispensing was the predictor of both OVS (p < 0.001) and ITP (p < 0.001) at 1-week. For OVS predictability, 70.8 % with OVS at dispensing > 91 points reported good OVS at 1-week and 73.4 % with OVS on dispensing ≤ 80 points reported poor OVS at 1-week. For ITP predictability, 74.6 % with OVS at dispensing > 94 points reported a positive ITP at 1-week and 65.9 % with OVS on dispensing ≤ 63 points reported negative ITP at 1-week. CONCLUSION: Overall vision satisfaction at the time of dispensing MFCLs is a powerful indicator of both OVS and ITP after 1-week of wear. Initial patient subjective assessments provide a clinically useful indicator of the likeliness of success.


Assuntos
Lentes de Contato Hidrofílicas , Presbiopia , Humanos , Masculino , Feminino , Acuidade Visual , Estudos Prospectivos , Visão Ocular
19.
Zhonghua Yan Ke Za Zhi ; 60(2): 120-126, 2024 Feb 11.
Artigo em Chinês | MEDLINE | ID: mdl-38296317

RESUMO

The number of contact lens wearers in China is increasing rapidly. Long-term contact lens wearing may induce or exacerbate tear film instability, and consequently affect the visual quality, ocular surface safety, and compliance of the wearers. To promote the safety and effectiveness of contact lens fitting, and to improve the visual quality and satisfaction of contact lens wearers, the Society of Contact Lens Safety Monitoring & Vision Health of Chinese Health Association has targeted to develop an expert consensus on the diagnosis and treatment of contact lens-associated dry eye. By referring to relevant literature and summarizing clinical experience, the clinical experts in corneal disease, pediatric ophthalmology and optometry have made repeated discussions to form this consensus, including the definition, pathological mechanisms, influencing factors, evaluation, prevention and treatment of contact lens-associated dry eye, for the reference of optometrists and ophthalmologists.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Doenças da Córnea , Síndromes do Olho Seco , Criança , Humanos , Consenso , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/terapia , Lentes de Contato/efeitos adversos , Lágrimas
20.
Ophthalmic Physiol Opt ; 44(2): 270-279, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38193312

RESUMO

PURPOSE: To review the rebound effect after cessation of different myopia control treatments. METHODS: A systematic review that included full-length randomised controlled studies (RCTs), as well as post-hoc analyses of RCTs reporting new findings on myopia control treatments rebound effect in two databases, PubMed and Web of Science, was performed according to the PRISMA statement. The search period was between 15 June 2023 and 30 June 2023. The Cochrane risk of bias tool was used to analyse the quality of the selected studies. RESULTS: A total of 11 studies were included in this systematic review. Unifying the rebound effects of all myopia control treatments, the mean rebound effect for axial length (AL) and spherical equivalent refraction (SER) were 0.10 ± 0.07 mm [-0.02 to 0.22] and -0.27 ± 0.2 D [-0.71 to -0.03] after 10.2 ± 7.4 months of washout, respectively. In addition, spectacles with highly aspherical lenslets or defocus incorporated multiple segments technology, soft multifocal contact lenses and orthokeratology showed lower rebound effects compared with atropine and low-level light therapy, with a mean rebound effect for AL and SER of 0.04 ± 0.04 mm [0 to 0.08] and -0.13 ± 0.07 D [-0.05 to -0.2], respectively. CONCLUSIONS: It appears that the different treatments for myopia control produce a rebound effect after their cessation. Specifically, optical treatments seem to produce less rebound effect than pharmacological or light therapies. However, more studies are required to confirm these results.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Humanos , Miopia/terapia , Atropina , Refração Ocular , Óculos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...